Getting Better Hospital Alarm Sounds Into a Global Standard
Date
2018-10Author
Subject
Metadata
Show full item recordAbstract
The reserved set of audible alarm signals embodied within the global medical device safety standard, IEC 60601-1-8, is known to be problematic and in need of updating. The current alarm signals are not only suboptimal, but there is also little evidence beyond learnability (which is known to be poor) that demonstrates their performance in realistic and representative clinical environments. In this article, we describe the process of first designing and then testing potential replacement audible alarm signals for IEC 60601-1-8, starting with the design of several sets of candidate sounds and initial tests on learnability and localizability, followed by testing in simulated clinical environments. We demonstrate that in all tests, the alarm signals selected for further development significantly outperform the current alarm signals. We describe the process of collecting considerably more data on the performance of the new sounds than exists for the current sounds, which ultimately will be of use to end users. We also reflect on the process and practice of working with the relevant committees and other practical issues beyond the science, which also need constant attention if the alarms we have developed are to be included successfully in an updated version of the standard.
Collections
Publisher
Journal
Volume
Issue
Pagination
Recommended, similar items
The following license files are associated with this item:
Related items
Showing items related by title, author, creator and subject.
-
Auditory icon alarms are more accurately and quickly identified than standard melodic alarms in a simulated clinical setting
Mcneer, R; Bodzin Horn, D; Bennett, C; Edworthy, Judy; Dudaryk, R (Lippincott, Williams & WilkinsUnited States, 2018-07)<jats:title>Abstract</jats:title><jats:sec><jats:title>Background</jats:title><jats:p>Current standard audible medical alarms are difficult to learn and distinguish from one another. Auditory icons represent a new type ... -
Acoustic features of auditory medical alarms - an experimental study of alarm volume
Schlesinger,, JJ; Baum, SH; Nash, K; Bruce, M; Ashmead, D; Shotwell, MS; Wallace, MT; Weinger, MB; Edworthy, Judy (Acoustical Society of AmericaUnited States, 2018-06-01)<jats:p>Audible alarms are a ubiquitous feature of all high-paced, high-risk domains such as aviation and nuclear power where operators control complex systems. In such settings, a missed alarm can have disastrous ... -
Can you hear it? Identifying the priority and function of overlapping auditory medical alarms
Parker, Cassie (University of Plymouth, 2021)This paper presents an experimental study that exhibits the differences seen between the recognition of high and moderate priority auditory alarms when played simultaneously. Past research has demonstrated that the current ...