BackgroundDiathermy smoke is a recognised occupational hazard, exposing staff to smoke equivalent to between 27 and 30 cigarettes each day.1 Consequences of inhalation include acute and chronic inflammatory lung conditions, carcinogenesis and exposure to pathogens including human immunodeficiency virus.2 The Health and Safety Executive recommends that, “If exposure to diathermy emissions can't be prevented then it should be adequately controlled … by Local Exhaust Ventilation”.3 Commercially available smoke extractors are expensive and costly to maintain. The units used in our hospital, for example, cost £2,040 and require perishable filters. Compatible, single-use diathermy pencils cost on average £16.08. We describe an alternative, simple, cost-effective surgeon-modified device, developed by the senior author.
DOI Link
Publication Date
2024-08-29
Publication Title
Annals of the Royal College of Surgeons of England
ISSN
0035-8843
Acceptance Date
2024-01-01
Deposit Date
2025-04-14
Additional Links
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.
First Page
2
Last Page
2
Recommended Citation
Brown, O., & Aroori, S. (2024) 'A surgeon-modified device for the evacuation of diathermy smoke.', Annals of the Royal College of Surgeons of England, , pp. 2-2. Available at: 10.1308/rcsann.2024.0061