Show simple item record

dc.contributor.authorAhlawat, S
dc.contributor.authorFayad, LM
dc.contributor.authorKhan, MS
dc.contributor.authorBredella, MA
dc.contributor.authorHarris, GJ
dc.contributor.authorEvans, DG
dc.contributor.authorFarschtschi, S
dc.contributor.authorJacobs, MA
dc.contributor.authorChhabra, A
dc.contributor.authorSalamon, JM
dc.contributor.authorWenzel, R
dc.contributor.authorMautner, VF
dc.contributor.authorDombi, E
dc.contributor.authorCai, W
dc.contributor.authorPlotkin, SR
dc.contributor.authorBlakeley, JO
dc.contributor.authorHanemann, Clemens Oliver
dc.date.accessioned2016-10-12T12:52:52Z
dc.date.available2016-10-12T12:52:52Z
dc.date.issued2016-08-16
dc.identifier.issn0028-3878
dc.identifier.issn1526-632X
dc.identifier.urihttp://hdl.handle.net/10026.1/6502
dc.description.abstract

OBJECTIVES: The Response Evaluation in Neurofibromatosis and Schwannomatosis (REiNS) International Collaboration Whole-Body MRI (WB-MRI) Working Group reviewed the existing literature on WB-MRI, an emerging technology for assessing disease in patients with neurofibromatosis type 1 (NF1), neurofibromatosis type 2 (NF2), and schwannomatosis (SWN), to recommend optimal image acquisition and analysis methods to enable WB-MRI as an endpoint in NF clinical trials. METHODS: A systematic process was used to review all published data about WB-MRI in NF syndromes to assess diagnostic accuracy, feasibility and reproducibility, and data about specific techniques for assessment of tumor burden, characterization of neoplasms, and response to therapy. RESULTS: WB-MRI at 1.5T or 3.0T is feasible for image acquisition. Short tau inversion recovery (STIR) sequence is used in all investigations to date, suggesting consensus about the utility of this sequence for detection of WB tumor burden in people with NF. There are insufficient data to support a consensus statement about the optimal imaging planes (axial vs coronal) or 2D vs 3D approaches. Functional imaging, although used in some NF studies, has not been systematically applied or evaluated. There are no comparative studies between regional vs WB-MRI or evaluations of WB-MRI reproducibility. CONCLUSIONS: WB-MRI is feasible for identifying tumors using both 1.5T and 3.0T systems. The STIR sequence is a core sequence. Additional investigation is needed to define the optimal approach for volumetric analysis, the reproducibility of WB-MRI in NF, and the diagnostic performance of WB-MRI vs regional MRI.

dc.format.extentS31-S39
dc.format.mediumPrint
dc.languageen
dc.language.isoen
dc.publisherOvid Technologies (Wolters Kluwer Health)
dc.subjectClinical Trials as Topic
dc.subjectHumans
dc.subjectMagnetic Resonance Imaging
dc.subjectMulticenter Studies as Topic
dc.subjectNeurilemmoma
dc.subjectNeurofibromatoses
dc.subjectNeurofibromatosis 1
dc.subjectNeurofibromatosis 2
dc.subjectSkin Neoplasms
dc.subjectWhole Body Imaging
dc.titleCurrent whole-body MRI applications in the neurofibromatoses
dc.typejournal-article
dc.typeConsensus Development Conference
dc.typeJournal Article
dc.typePractice Guideline
plymouth.author-urlhttps://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000382328100006&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=11bb513d99f797142bcfeffcc58ea008
plymouth.issue7 Supplement 1
plymouth.volume87
plymouth.publication-statusPublished
plymouth.journalNeurology
dc.identifier.doi10.1212/WNL.0000000000002929
plymouth.organisational-group/Plymouth
plymouth.organisational-group/Plymouth/Faculty of Health
plymouth.organisational-group/Plymouth/Faculty of Health/Peninsula Medical School
plymouth.organisational-group/Plymouth/REF 2021 Researchers by UoA
plymouth.organisational-group/Plymouth/REF 2021 Researchers by UoA/UoA01 Clinical Medicine
plymouth.organisational-group/Plymouth/Research Groups
plymouth.organisational-group/Plymouth/Research Groups/Institute of Translational and Stratified Medicine (ITSMED)
plymouth.organisational-group/Plymouth/Research Groups/Institute of Translational and Stratified Medicine (ITSMED)/CBR
plymouth.organisational-group/Plymouth/Users by role
plymouth.organisational-group/Plymouth/Users by role/Academics
plymouth.organisational-group/Plymouth/Users by role/Researchers in ResearchFish submission
dc.publisher.placeUnited States
dcterms.dateAccepted2016-05-26
dc.rights.embargodate2017-8-15
dc.identifier.eissn1526-632X
dc.rights.embargoperiodNo embargo
rioxxterms.versionofrecord10.1212/WNL.0000000000002929
rioxxterms.licenseref.urihttp://www.rioxx.net/licenses/all-rights-reserved
rioxxterms.licenseref.startdate2016-08-16
rioxxterms.typeJournal Article/Review


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record


All items in PEARL are protected by copyright law.
Author manuscripts deposited to comply with open access mandates are made available in accordance with publisher policies. Please cite only the published version using the details provided on the item record or document. In the absence of an open licence (e.g. Creative Commons), permissions for further reuse of content should be sought from the publisher or author.
Theme by 
Atmire NV