SLURRY ATOMISATION SYSTEM FOR PROCESS CONTROL
Abstract
The mechanistic processes of slurry atomisation - Direct Current Plasma - Atomic Emission Spectroscopy (DCP-AES) were investigated using excitation temperature (Texc) measurements , simplex optimisation, particle transport experiments and computerised tomography .
Collections
Publisher
University of Plymouth
Commissioning body
School of Geography, Earth and Environmental Sciences
The following license files are associated with this item: